留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

两种透明介质微小折射率差高精度测量的新方法

吴婷 邹岩 李之通 惠勇凌 李强

吴婷, 邹岩, 李之通, 惠勇凌, 李强. 两种透明介质微小折射率差高精度测量的新方法[J]. 红外与激光工程, 2017, 46(4): 417005-0417005(6). doi: 10.3788/IRLA201746.0417005
引用本文: 吴婷, 邹岩, 李之通, 惠勇凌, 李强. 两种透明介质微小折射率差高精度测量的新方法[J]. 红外与激光工程, 2017, 46(4): 417005-0417005(6). doi: 10.3788/IRLA201746.0417005
Wu Ting, Zou Yan, Li Zhitong, Hui Yongling, Li Qiang. Novel approach for high-precision measurement of micre refractive index difference of two transparent mediums[J]. Infrared and Laser Engineering, 2017, 46(4): 417005-0417005(6). doi: 10.3788/IRLA201746.0417005
Citation: Wu Ting, Zou Yan, Li Zhitong, Hui Yongling, Li Qiang. Novel approach for high-precision measurement of micre refractive index difference of two transparent mediums[J]. Infrared and Laser Engineering, 2017, 46(4): 417005-0417005(6). doi: 10.3788/IRLA201746.0417005

两种透明介质微小折射率差高精度测量的新方法

doi: 10.3788/IRLA201746.0417005
基金项目: 

国家自然科学基金(61378023)

详细信息
    作者简介:

    吴婷(1990-),女,硕士生,主要从事高功率固体激光器方面的研究。Email:wuting@bjut.edu.cn

  • 中图分类号: TN247

Novel approach for high-precision measurement of micre refractive index difference of two transparent mediums

  • 摘要: 对现有折射率的测量技术进行分析,提出了一种测量两种透明介质间微小折射率差的新方法。首先,介绍了微小折射率差干涉测量方法的原理,并对该测量原理利用Zemax光学仿真软件进行了理论模拟论证。该实验中首先,采用热键合技术制备包含两种被测量材料的组合平板;其次,利用干涉测量仪及外光路测量样件界面区域不同入射角下的光程差;再者,利用几何光学中的折射定律,推导折射率分布与干涉光程差的关系式。最后,通过二次曲线拟合获得正入射时的光程差微小变化值、换算得到样件两种材料的折射率差值。实验测量了1 at.% Yb3+::YAG晶体与YAG晶体的热键合样品的折射率差,测量值为5.4110-5,测量系统精度10-7量级。结果表明:该测量方法原理简单、操作简便,测量精度高。
  • [1] Mu Xiaodong, Stephanie Meissner, Helmuth Meissner, et al. High efficiency Yb:YAG crystalline fiber-waveguide lasers[J]. Optics Letters, 2001, 39(21):6331-6333.
    [2] Mu Xiaodong, Helmuth Meissner, Huai-Chuan Lee. True crystalline fibers:double-clad LMA design concept of Tm:YAG-Core fiber and mode simulation[C]//SPIE, 2012, 8237:8237M-1-5.
    [3] Liao Suying, Gong Mali. New progress of large mode area fiber[J]. Infrared and Laser Engineering, 2011,40(3):455-462. (in Chinese)廖素英, 巩马理. 大模场光纤研究的新进展[J]. 红外与激光工程, 2011, 40(3):455-462.
    [4] Bhatcharya J C. Measurement of the refractive index using the Talbot effect and moire techniques[J]. Applied Optics, 1989, 28(13):2600-2604.
    [5] Yeh Y, Yen Liang. Simultaneous measurement of refractive index and thickness of brefringent wave plates[J]. Appl Opt, 2008, 47(10):1457-1464.
    [6] Dalmon M, Masumura A. High accuracy measurement of the refractive index and its temperature coefficient of calcium fluoride in a wide wavelength range from 138 to 2326[J]. Applied Optics, 2002, 41(25):5275-5281.
    [7] Burnett J H, Gupta R, Griesmann U. Absolute refractive indices and thermal coefficient of CaF2, SrF2, BaF2, and LiF near 157 nm[J]. Appl Opt, 2002, 41(13):2508-2513.
    [8] Galli M, Marabelli F, Guizzetti G. Direct measurement of refractive-index dispersion of transparent media by white-light interferometry[J]. Appl Opt, 2003, 42(19):3010-3914.
    [9] Yasuaki Hori, Akiko Hirai, Kaoru Minoshima, et al. High-accuracy interferometer with a prism pair for measurement of the absolute refractive index of glass[J]. Applied Optics, 2009, 48(11):2045-2049.
    [10] White K I. Practical application of the refracted near-field technique for the measurement of optical fiber refractive index profile[J]. Opt Quantum Electron, 1976, 11(4):669-671.
    [11] Morishita K. Index profiling of three-dimensional optical waveguides by the propagation-mode near-filed method[J]. Light Wave Technology, 1986, 4(8):1120-1124.
    [12] Pogossian S P. A new approach to determining the waveguide mode index distribution[J]. Opt Quantum, 1993, 25(2):417-422.
    [13] Vladimir A B, Anton V B, Denis E P. Direct method determination of the equivalent refractive index profile of the multimode optical fiber by measured impulse responses due to scanning output fiber end[C]//SPIE, 2015, 9533:95330W-1.
    [14] Marcuse D. Refractive index determination by the focusing method[J]. Appl Opt, 1979, 18(1):9-13.
    [15] Ikeda M, Tateda M, Yoshikiyo H. Refractive index profile of a graded index fiber, measurement by a reflection method[J]. Applied Optics, 1975, 14(4):814-815.
    [16] Zhou Hongying, Chen Jiabi, Hu Qunhua, et al. Investigation of scan to measure the distributing of refraction ratio of section plane[J]. Infrared and Laser Engineering, 2007, 36(S1):159-161.(in Chinese)周鸿颖, 陈家璧,胡群华, 等. 利用扫描法测量预制棒折射率[J]. 红外与激光工程, 2007, 36(S1):159-161.
    [17] Hamza A A, Mabrouk M A. Determination of GR-IN optical fiber parameters from transverse interferograms considering the refraction of incident ray by the fiber[J]. Optical Communications, 2001, 200(1-6):131-138.
    [18] Yan X, Liu L. Determining the optical properties of highly oriented fibers using a multiple-beam technique[J]. Journal of Optics A:Pure Applied Optics, 2001, 3(5):421-427.
    [19] Hamza A A, Sokkar T Z N, Ghander A M, et al. On the determination of the refractive index of a fiber:II. graded index fibers[J]. Pure Applied Optics, 1995, 4:161-177.
  • [1] 高宇森, 高楠, 倪育博, 孟召宗, 邵金凤, 张宗华.  全方位相机与转轴位姿标定方法研究 . 红外与激光工程, 2023, 52(8): 20230425-1-20230425-11. doi: 10.3788/IRLA20230425
    [2] 陈兰剑, 席崇宾, 周健, 聂晓明, 王琦, 黄荣, 向志毅, 金世龙.  用于导航定位的激光多普勒测速技术研究进展 . 红外与激光工程, 2023, 52(6): 20230143-1-20230143-13. doi: 10.3788/IRLA20230143
    [3] 吴金云, 杨剑, 高伟超, 张引发.  基于里德堡原子的无线电光学测量及其光谱处理技术(特邀) . 红外与激光工程, 2023, 52(6): 20230264-1-20230264-25. doi: 10.3788/IRLA20230264
    [4] 李小艳, 李义春, 李中天, 王映德, 王立成, 王艳辉, 田振男.  玻璃波导有效折射率的原位测量(特邀) . 红外与激光工程, 2022, 51(10): 20220491-1-20220491-8. doi: 10.3788/IRLA20220491
    [5] 郑晨, 冯文林, 何思杰, 李邦兴.  用于测量折射率的光纤迈克尔逊干涉型传感器 . 红外与激光工程, 2022, 51(5): 20210327-1-20210327-5. doi: 10.3788/IRLA20210327
    [6] 刘今越, 翟志国, 贾晓辉, 薛路明, 李铁军.  基于面结构光的工件内壁点云旋转拼接研究 . 红外与激光工程, 2022, 51(9): 20210952-1-20210952-7. doi: 10.3788/IRLA20210952
    [7] 邵新杰, 潘硕, 宋彬, 李晓磊, 唐香珺.  深孔内表面检测点云拼接技术研究 . 红外与激光工程, 2021, 50(12): 20210210-1-20210210-8. doi: 10.3788/IRLA20210210
    [8] 胡凯, 丛海佳, 陈凡胜, 金钢.  宽视场航天相机像面测量技术 . 红外与激光工程, 2021, 50(5): 20200336-1-20200336-7. doi: 10.3788/IRLA20200336
    [9] 赵媛媛, 肖作江, 梁旭.  基于光谱干涉技术的玻璃厚度及折射率测量方法 . 红外与激光工程, 2020, 49(2): 0213004-0213004. doi: 10.3788/IRLA202049.0213004
    [10] 王辰星, 达飞鹏.  基于经验模态分解法的光学条纹图像处理研究进展 . 红外与激光工程, 2020, 49(3): 0303013-0303013-11. doi: 10.3788/IRLA202049.0303013
    [11] 王多书, 李佑路, 李凯朋, 王济洲, 董茂进.  红外光学薄膜材料折射率温度特性的研究方法 . 红外与激光工程, 2018, 47(4): 404006-0404006(5). doi: 10.3788/IRLA201847.0404006
    [12] 杨亮亮.  衍射光学元件斜入射衍射效率的测量 . 红外与激光工程, 2018, 47(1): 117003-0117003(5). doi: 10.3788/IRLA201847.0117003
    [13] 孙沁园, 陈磊, 郑东晖, 朱文华, 张瑞, 丁煜.  采用短相干光源的动态斐索干涉仪 . 红外与激光工程, 2018, 47(2): 220001-0220001(7). doi: 10.3788/IRLA201847.0220001
    [14] 曹智睿, 付跃刚.  点源透射比测试的高性能光陷阱技术研究 . 红外与激光工程, 2017, 46(1): 117006-0117006(7). doi: 10.3788/IRLA201746.0117006
    [15] 孙文卿, 陈磊, 李金鹏, 乌兰图雅, 何勇.  非圆孔径离散采样点正交多项式波前拟合 . 红外与激光工程, 2015, 44(3): 1068-1072.
    [16] 戴士杰, 易丹, 李伟超, 常淑英, 王志平.  分段非均匀条纹生成方法及其在双频解相位中的应用 . 红外与激光工程, 2015, 44(9): 2849-2853,2857.
    [17] 韩志刚, 陈磊.  对包络变化及移相误差不敏感的宽带光八步移相算法 . 红外与激光工程, 2015, 44(4): 1236-1242.
    [18] 梅金硕, 舒昌, 贺讯军, 张狂, 吴群.  基于正折射率材料参数的旋转放大光学变换器件 . 红外与激光工程, 2014, 43(2): 493-496.
    [19] 潘继环, 苏安, 蒙成举.  介质折射率对光子晶体量子阱滤波性能的调制 . 红外与激光工程, 2014, 43(3): 833-837.
    [20] 王涌鹏, 罗佳, 白剑, 梁宜勇.  高精度长焦距测量系统反射镜安装误差分析 . 红外与激光工程, 2014, 43(2): 562-568.
  • 加载中
计量
  • 文章访问数:  302
  • HTML全文浏览量:  42
  • PDF下载量:  82
  • 被引次数: 0
出版历程
  • 收稿日期:  2016-08-05
  • 修回日期:  2016-09-15
  • 刊出日期:  2017-04-25

两种透明介质微小折射率差高精度测量的新方法

doi: 10.3788/IRLA201746.0417005
    作者简介:

    吴婷(1990-),女,硕士生,主要从事高功率固体激光器方面的研究。Email:wuting@bjut.edu.cn

基金项目:

国家自然科学基金(61378023)

  • 中图分类号: TN247

摘要: 对现有折射率的测量技术进行分析,提出了一种测量两种透明介质间微小折射率差的新方法。首先,介绍了微小折射率差干涉测量方法的原理,并对该测量原理利用Zemax光学仿真软件进行了理论模拟论证。该实验中首先,采用热键合技术制备包含两种被测量材料的组合平板;其次,利用干涉测量仪及外光路测量样件界面区域不同入射角下的光程差;再者,利用几何光学中的折射定律,推导折射率分布与干涉光程差的关系式。最后,通过二次曲线拟合获得正入射时的光程差微小变化值、换算得到样件两种材料的折射率差值。实验测量了1 at.% Yb3+::YAG晶体与YAG晶体的热键合样品的折射率差,测量值为5.4110-5,测量系统精度10-7量级。结果表明:该测量方法原理简单、操作简便,测量精度高。

English Abstract

参考文献 (19)

目录

    /

    返回文章
    返回