[1] Li Xiangxian, Wang Zhen, Xu Liang, et al. Study on temperature dependence of the greenhouse gases and carbon isotope ratio spectral analysis[J]. Infrared and Laser Engineering, 2015, 44(4):1178-1185. (in Chinese)
[2] Tong Jingjing, Gao Minguang, Xu Liang, et al. Measurement and study of 1,3-butadiene based on open path FTIR spectroscopy[J]. Infrared and Laser Engineering, 2013, 42(1):239-243. (in Chinese)
[3] Li Yan, Gao Minguang, Xu Liang, et al. Based on trigger sampling method and phase correction of infrared spectrum measurement applications[J]. Spectroscopy and Spectral Analysis, 2015, 35(7):2054-2059. (in Chinese)
[4] Saptari V. Fourier-Transform Spectroscopy Instrumentation Engineering[M]//Tutorial Texts in Optical Engineering volume TT61. Washington USA:SPIE Press, 2004.
[5] Minami K, Kawata S, Minami S. Zero-crossing sampling of Fourier-transform interferograms and spectrum reconstruction using the real-zero interpolation method[J]. Applied Optics, 1992, 31(29):6322-6327.
[6] Li Zhigang, Wang Shurong, Han Wenhui, et al. Data sampling of fourier transform spectrometer interferogram using laser interference fringe[J]. Journal of Optoelectronics Laser, 2000,11(5):503-506. (in Chinese)
[7] Brault J W. New approach to high-precision Fourier transform spectrometer design[J]. Applied Optics, 1996, 35(16):2891-2896.
[8] Brasunas J C, Cushman G M. Uniform time-sampling Fourier transform spectroscopy[J]. Applied Optics, 1997, 36(10):2206-2210.
[9] Pougatchev N S, Campbell J F, Regan C R, et al. Advanced technologies high resolution Fourier transform spectrometer for atmospheric studies[C]//Proceeding of 2000 IEEE, 2000:237-243.
[10] Davis S P, Abrams M C, Brault J W. Fourier transform spectrometry[M]. San Diego, California:Academic Press, 2001.
[11] Palchetti L, Lastrucci D. Spectral noise due to sampling errors in fourier-transform spectroscopy[J]. Applied Optics, 2001, 40(19):3235-3243.
[12] Griffiths P R, de Haseth J A., Fourier Transform Infrared Spectrometry[M]. 2nd ed. New York:Wiley Sons,2007.
[13] Ren Libing, Wei Haoyun, Li Yan. Digital filter method of oversampling Fourier transform infrared spectrometer[J]. Infrared and Laser Engineering, 2012, 41(6):1438-1441. (in Chinese)
[14] Turner A, Hoult R A, Forster M D. Digitisation of interferograms in Fourier Transform Spectroscopy:US, patent5914780[P]. 1999-06-22.
[15] Alber G M, Marshall A G. Effect of sampling rate on Fourier transform spectra:oversampling is overrated[J]. Applied Spectroscopy, 1990, 44(7):1111-1116.
[16] Ren Libing, Wei Haoyun, Li Yan. Study on the application of soft zero-crossing detection in the infrared spectral measurement system[C]//Proceeding of the Chinese Optical Society, 2010. (in Chinese)
[17] Zhou Feng, Zhao Chunyu, Huang Zhenyu, et al. Time-domain linear interpolation algorithm and its error analysis for estimating signal period[J]. Chinese Journal of Scientific Instrument, 2011, 32(8):1725-1730. (in Chinese)
[18] Wu Jie, Liu Kaipei, Le Jian, et al. Study on harmonic analysis based on cubic spline interpolated arithmetic fourier transform[J]. Electrical Measurement Instrumentation, 2016, 53(1):15-31. (in Chinese)
[19] Li Xinfu, Li Xiaofan. Comparison of the accuracy for fractal and lagrange interpolation[J]. Journal of Natural Science of Heilongjiang University, 2008, 25(3):323-325. (in Chinese)