留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

用于探测器中红外绝对光谱响应度测量的激光源

赵坤 史学舜 刘长明 刘玉龙 陈海东 刘红博 陈坤峰 李立功

赵坤, 史学舜, 刘长明, 刘玉龙, 陈海东, 刘红博, 陈坤峰, 李立功. 用于探测器中红外绝对光谱响应度测量的激光源[J]. 红外与激光工程, 2016, 45(7): 705005-0705005(7). doi: 10.3788/IRLA201645.0705005
引用本文: 赵坤, 史学舜, 刘长明, 刘玉龙, 陈海东, 刘红博, 陈坤峰, 李立功. 用于探测器中红外绝对光谱响应度测量的激光源[J]. 红外与激光工程, 2016, 45(7): 705005-0705005(7). doi: 10.3788/IRLA201645.0705005
Zhao Kun, Shi Xueshun, Liu Changming, Liu Yulong, Chen Haidong, Liu Hongbo, Chen Kunfeng, Li Ligong. Laser source used in accurate measurement of mid-infrared absolute spectral responsivity of detectors[J]. Infrared and Laser Engineering, 2016, 45(7): 705005-0705005(7). doi: 10.3788/IRLA201645.0705005
Citation: Zhao Kun, Shi Xueshun, Liu Changming, Liu Yulong, Chen Haidong, Liu Hongbo, Chen Kunfeng, Li Ligong. Laser source used in accurate measurement of mid-infrared absolute spectral responsivity of detectors[J]. Infrared and Laser Engineering, 2016, 45(7): 705005-0705005(7). doi: 10.3788/IRLA201645.0705005

用于探测器中红外绝对光谱响应度测量的激光源

doi: 10.3788/IRLA201645.0705005
基金项目: 

国家重点基础研究发展计划(863计划);空间辐射测量基准源研制基金(2015AA123702);国防技术基础项目(J3120BA001)

详细信息
    作者简介:

    赵坤(1986-),男,工程师,博士,主要从事光学辐射测量方向的研究。Email:kunzhao41@163.com

  • 中图分类号: TN215

Laser source used in accurate measurement of mid-infrared absolute spectral responsivity of detectors

  • 摘要: 为了实现中红外探测器绝对光谱响应度高准确度的测量,从理论和实验上研究了中红外波段激光的功率稳定性的提高和光束质量的优化方法。采用声光调制和反馈控制的方法,把中红外激光的功率稳定性提高到0.1%以内;根据高斯光束传输理论计算了所需空间滤波器的各项参数,设计了中红外空间滤波器,搭建了相应的实验装置,显著提高了中红外激光光束质量。为中红外绝对光谱响应度的高准确度测量提供了一个可靠的中红外波段激光光源。
  • [1] Fan Jinxiang, Li Liang, Li Wenjun. Development of direct infrared countermeasure system and technology[J]. Infrared and Laser Engineering, 2015, 44(3):789-794. (in Chinese)范晋祥, 李亮, 李文军. 定向红外对抗系统与技术的发展[J]. 红外与激光工程, 2015, 44(3):789-794.
    [2] Xu Hanlie, Hu Xiuqing, Xu Na, et al. Discrimination and correction for solar contamination on mid-infrared band of FY-3C/VIRR[J]. Optics and Precision Engineering, 2015, 23(7):1874-1879. (in Chinese)徐寒列, 胡秀清, 徐娜, 等. FY-3C/可见光红外扫描辐射计中红外通道太阳污染的识别和修正[J]. 光学精密工程, 2015, 23(7):1874-1879.
    [3] Liu Jianguo, Liu Wenqing, Zhang Yujun, et al. Detection of formaldehyde using mid-infrared difference-frequency-based tunable absorption spectrometer at room temperature[J]. Infrared and Laser Engineering, 2006, 35(S):211-215.(in Chinese)刘建国, 刘文清, 张玉钧, 等. 差频中红外激光光谱技术探测大气甲醛污染研究[J]. 红外与激光工程, 2006, 35(S):211-215.
    [4] Hoyt C, Foukal P. Cryogenic radiometers and their application to the metrology[J]. Metrologia, 1991, 28(3):163-167.
    [5] Xueshun S, Kunfeng C, Hongyuan L, et al. Experimental study on absolute spectral responsivity value transfer with cryogenic radiometer[C]//SPIE, 2009, 7511:75111A-1-6.
    [6] Shi Xueshun, Chen Kunfeng, Wang Hengfei, et al. Experimental studies on Si trap detector absolute spectral responsivity calibration[J]. Optics Optoelectronic Technology, 2009, 7(5):63-65. (in Chinese)史学舜, 陈坤峰, 王恒飞, 等. 硅陷阱探测器绝对光谱响应率校准实验研究[J]. 光学与光电技术, 2009, 7(5):63-65.
    [7] Shi Xueshun, Liu Changming, Liu Yulong, et al. Absolute spectral responsivity of silicon trap detector based on absolute cryogenic radiometer[C]//the International Conference on Photonics and Optical Engineering, Proc.of SPIE, 2014, 9449:94490U-1-94490U-6.
    [8] Liu Changming, Shi Xueshun, Liu Yulong, et al. Determination of absolute spectral response and quantum efficiency of Si trap detector in band of 325-980 nm[J]. Journal of Optoeletronics Laser, 2015, 26(4):667-670. (in Chinese)刘长明, 史学舜, 刘玉龙, 等. 硅陷阱探测器在325~980 nm波段的绝对光谱响应率和量子效率测定[J]. 光电子激光, 2015, 26(4):667-670.
    [9] Liu Yulong, Liu Changming, Shi Xueshun, et al. Development of the transfer standard of near infrared absolute spectral response[J]. Journal of Astronautic Metrology and Measurement, 2015, 35(3):48-54. (in Chinese)刘玉龙, 刘长明, 史学舜, 等. 近红外绝对光谱响应度传递标准的研制[J]. 宇航计测技术, 2015, 35(3):48-54.
    [10] Pan Qikun. Progress of mid-infrared solid-state laser[J]. Chinese Optics, 2015, 8(4):557-566. (in Chinese)潘其坤. 中红外固体激光器研究进展[J]. 中国光学, 2015, 8(4):557-566.
    [11] Tan Gaijuan, Xie Jijiang, Zhang Laiming, et al. Recent progress in mid-infrared laser technology[J]. Chinese Optics, 2013, 6(4):501-512. 谭改娟, 谢冀江, 张来明, 等. 中波红外激光技术最新进展[J]. 中国光学, 2013, 6(4):501-512.
    [12] Su Hui, Li Zhiping, Duan Yanmin, et al. Intra-cavity singly resonant optical parametric oscillatro based on magnesium-doped periodically poled lithium niobate[J]. Optics and Precision Engineering, 2013, 21(6):1404-1409. (in Chinese)苏辉, 李志平, 段延敏,等. 基于掺镁周期极化铌酸锂晶体的内腔单共振连续可调谐光参量振荡器[J]. 光学精密工程, 2013, 21(6):1404-1409.
    [13] Sun Quanshe, Chen Kunfeng, Shi Xueshun. Mid infrared laser power stabilizer[J]. Infrared and Laser Engineering, 2015, 44(7):2127-2131. (in Chinese)孙权社, 陈坤峰, 史学舜. 中红外激光器功率稳定器技术[J]. 红外与激光工程, 2015, 44(7):2127-2131.
    [14] Gao Miao, Shao Xiaopeng, Wang Lin, et al. Power stabilization system of medium wave infrared laser based on acousto-optic modulator[J]. Infrared and Laser Engineering, 2015,44(7):1975-1979. (in Chinese)高苗, 绍晓鹏, 王琳,等. 基于声光调制的中波红外激光功率稳定系统[J]. 红外与激光工程, 2015, 44(7):1975-1979.
  • [1] 王路达, 吴伟冲, 朱占达, 白振旭, 惠勇凌, 雷訇, 李强.  基于光谱合束的双波长输出Nd:YAG固体激光器 . 红外与激光工程, 2024, 53(1): 20230411-1-20230411-6. doi: 10.3788/IRLA20230411
    [2] 杜俊廷, 常冰, 李照宇, 张浩, 秦琛烨, 耿勇, 谭腾, 周恒, 姚佰承.  中红外光学频率梳:进展与应用(特邀) . 红外与激光工程, 2022, 51(3): 20210969-1-20210969-15. doi: 10.3788/IRLA20210969
    [3] 李国会, 杜应磊, 徐宏来, 向汝建, 吴晶, 谢川林, 周志强, 刘章文, 向振佼, 张秋实.  双变形镜对Yb:YAG板条激光器光束质量校正技术 . 红外与激光工程, 2022, 51(8): 20210800-1-20210800-11. doi: 10.3788/IRLA20210800
    [4] 淡金川, 谭少阳, 王邦国, 肖垚, 邓国亮, 王俊.  波导结构对905 nm隧道结级联半导体激光器的光束质量和功率的影响 . 红外与激光工程, 2022, 51(5): 20210979-1-20210979-7. doi: 10.3788/IRLA20210979
    [5] 付敏, 李智贤, 王泽锋, 陈子伦.  高光束质量3×1光纤功率合束器的研制 . 红外与激光工程, 2022, 51(5): 20210354-1-20210354-7. doi: 10.3788/IRLA20210354
    [6] 钱俊宇, 彭宇杰, 李妍妍, 黎文开, 冯壬誉, 沈丽雅, 冷雨欣.  中红外超强超短激光研究进展(特邀) . 红外与激光工程, 2021, 50(8): 20210456-1-20210456-10. doi: 10.3788/IRLA20210456
    [7] 杨婷婷, 陈红山, 刘贺言, 郝婧婕, 张金伟.  基于孤子自压缩的高功率少周期2 μm激光产生(特邀) . 红外与激光工程, 2021, 50(8): 20210355-1-20210355-7. doi: 10.3788/IRLA20210355
    [8] 白翔, 何洋, 于德洋, 张阔, 陈飞.  小型化高光束质量MgO: PPLN中红外光参量振荡器 . 红外与激光工程, 2020, 49(7): 20190512-1-20190512-6. doi: 10.3788/IRLA20190512
    [9] 同晖, 覃治鹏, 谢国强, 钱列加.  飞秒光参量振荡器的光谱净化和稳定性提升(特邀) . 红外与激光工程, 2020, 49(12): 20201060-1-20201060-5. doi: 10.3788/IRLA20201060
    [10] 柏刚, 沈辉, 杨依枫, 赵翔, 张璟璞, 何兵, 周军.  光谱合成激光阵列指向偏差的光束特性分析 . 红外与激光工程, 2018, 47(1): 103010-0103010(6). doi: 10.3788/IRLA201847.0103010
    [11] 贾志旭, 姚传飞, 李真睿, 贾世杰, 赵志鹏, 秦伟平, 秦冠仕.  基于氟碲酸盐光纤的高功率中红外超连续光源(特邀) . 红外与激光工程, 2018, 47(8): 803004-0803004(11). doi: 10.3788/IRLA201847.0803004
    [12] 景文博, 张汝平, 王晓曼, 赵洁, 杨世钰, 高洋洋.  CCD的非线性响应特性对光束质量测量的影响及修正 . 红外与激光工程, 2017, 46(8): 817004-0817004(8). doi: 10.3788/IRLA201746.0817004
    [13] 陈海东, 赵坤, 史学舜, 刘长明, 刘玉龙, 刘红博.  基于长波红外探测器绝对光谱响应度测量的激光源 . 红外与激光工程, 2017, 46(12): 1205002-1205002(7). doi: 10.3788/IRLA201746.1205002
    [14] 王彬, 孙洪涛, 于永吉, 张健, 金光勇.  高功率声光调Q主振荡功率放大器 . 红外与激光工程, 2016, 45(12): 1205003-1205003(5). doi: 10.3788/IRLA201645.1205003
    [15] 李峙, 尧舜, 高祥宇, 潘飞, 贾冠男, 王智勇.  半导体激光器堆栈快轴光束质量计算的研究 . 红外与激光工程, 2015, 44(1): 85-90.
    [16] 张阔, 陆君, 杨贵龙, 陈飞, 李殿军, 郑长彬, 郭劲.  大功率TEA CO2 激光远场发散角评估方法 . 红外与激光工程, 2015, 44(8): 2286-2291.
    [17] 高苗, 邵晓鹏, 王琳, 史学舜, 孙昊洋, 丁钟奎, 孙华梁, 张彦杰, 刘玉龙.  基于声光调制的中波红外激光功率稳定系统 . 红外与激光工程, 2015, 44(7): 1975-1979.
    [18] 张世强, 蔡雷, 张政, 卢慧玲, 周松青, 瞿谱波.  超连续谱激光光束质量特性 . 红外与激光工程, 2014, 43(5): 1428-1432.
    [19] 董繁龙, 赵方舟, 葛廷武, 王智勇.  光纤弯曲对掺镱光纤激光器光束质量的影响 . 红外与激光工程, 2014, 43(11): 3565-3569.
    [20] 郭汝海, 陈宁, 时魁, 王兵, 施龙.  高功率激光系统中内光路热变形的仿真及实验研究 . 红外与激光工程, 2013, 42(11): 2925-2930.
  • 加载中
计量
  • 文章访问数:  508
  • HTML全文浏览量:  99
  • PDF下载量:  144
  • 被引次数: 0
出版历程
  • 收稿日期:  2015-11-05
  • 修回日期:  2015-12-03
  • 刊出日期:  2016-07-25

用于探测器中红外绝对光谱响应度测量的激光源

doi: 10.3788/IRLA201645.0705005
    作者简介:

    赵坤(1986-),男,工程师,博士,主要从事光学辐射测量方向的研究。Email:kunzhao41@163.com

基金项目:

国家重点基础研究发展计划(863计划);空间辐射测量基准源研制基金(2015AA123702);国防技术基础项目(J3120BA001)

  • 中图分类号: TN215

摘要: 为了实现中红外探测器绝对光谱响应度高准确度的测量,从理论和实验上研究了中红外波段激光的功率稳定性的提高和光束质量的优化方法。采用声光调制和反馈控制的方法,把中红外激光的功率稳定性提高到0.1%以内;根据高斯光束传输理论计算了所需空间滤波器的各项参数,设计了中红外空间滤波器,搭建了相应的实验装置,显著提高了中红外激光光束质量。为中红外绝对光谱响应度的高准确度测量提供了一个可靠的中红外波段激光光源。

English Abstract

参考文献 (14)

目录

    /

    返回文章
    返回