[1]
|
Hamazaki T, Kaneko Y, Kuze A, et al. Fourier transform spectrometer for greenhouse gases observing satellite (GOSAT)[C]//Enabling Sensor Platform Technologies for Spaceborne Remote Sensing. International Society for Optics and Photonics, 2005. |
[2]
|
Frankenberg C, Pollock R, Lee R A M, et al. The orbiting carbon observatory (OCO-2):spectrometer performance evaluation using pre-launch direct sun measurements[J]. Atmospheric Measurement Techniques, 2015, 8(1):301-313. |
[3]
|
O'Brien D M, Rayner P J. Global observations of the carbon budget, 2, CO2 column from differential absorption of reflected sunlight in the 1.61m band of CO2[J]. Journal of Geophysical Research, 2002, 107(D18):4354. |
[4]
|
Harlander J M, Roesler F L, Englert C R, et al. Spatial heterodyne spectroscopy for high spectral resolution space-based remote sensing[J]. Optics Photonics News, 2004, 15(15):46-51. |
[5]
|
Roesler F L, Harlander J M. Spatial heterodyne spectroscopy for atmospheric remote sensing[C]//Proc SPIE, 1999, 3756:337-345. |
[6]
|
Harlander J M, Roesler F L, Chakrabarti S. Spatial heterodyne spectroscopy:a novel interferometric techni-que for the FUV[C]//SPIE, 1990, 1344:10.1117/12.23275. |
[7]
|
Rodgers C D. Retrieval of atmospheric temperature and composition from remote measurements of thermal radiation[J]. Rev Geophys and Space Phys, 1976, 14(4):609-624. |
[8]
|
Francois-Marie Breon, Philippe Ciais. Spaceborne remote sensing of greenhouse gas concentrations[J]. Comptes Rendus Geoscience, 2009, 342(2010):412-424. |
[9]
|
Luo Haiyan, Li Shuang, Shi Hailiang, et al. Optical design of imaging system based on spatial heterodyne spectrometer[J]. Infrared and Laser Engineering, 2016, 45(8):228-233. (in Chinese)罗海燕, 李双, 施海亮, 等. 空间外差光谱仪成像光学系统设计[J]. 红外与激光工程, 2016, 45(8):228-233. |
[10]
|
Shi Hailiang, Li Zhiwei, Luo Haiyan, et al. Error correction of spectral calibration for hyper-spectral atmosphere CO2 monitoring instrument[J]. Spectroscopy and Spectral Analysis, 2016, 36(7):2296-2299. (in Chinese)施海亮, 李志伟, 罗海燕, 等. 超光谱大气CO2监测仪光谱定标误差修正[J]. 光谱学与光谱分析, 2016, 36(7):2296-2299. |
[11]
|
Li Zhiwei, Xiong Wei, Shi Hailiang, et al. Research on laboratory calibration technology of dpace heterodyne dpectrometer[J]. Acta Optica Sinica, 2014, 34(4):0430002. (in Chinese)李志伟, 熊伟, 施海亮, 等. 空间外差光谱仪实验室定标技术研究[J]. 光学学报, 2014, 34(4):0430002. |
[12]
|
Shi Hailiang, Xiong Wei, Zou Mingmin, et al. Calibration method of spatial heterodyne spectrometer[J]. Spectroscopy and Spectral Analysis, 2010, 30(6):1683-1687. (in Chinese)施海亮, 熊伟, 邹铭敏, 等. 空间外差光谱仪定标方法研究[J]. 光谱学与光谱分析, 2010, 30(6):1683-1687. |