Volume 43 Issue 9
Oct.  2014
Turn off MathJax
Article Contents

Hou Zhijin, Si Junjie, Wang Wei, Lv Yanqiu, Wang Jinchun, Chen Xiangwei. Resistance selection of blind sensitive element in PC PbS IRFPA detector fabrication[J]. Infrared and Laser Engineering, 2014, 43(9): 2793-2797.
Citation: Hou Zhijin, Si Junjie, Wang Wei, Lv Yanqiu, Wang Jinchun, Chen Xiangwei. Resistance selection of blind sensitive element in PC PbS IRFPA detector fabrication[J]. Infrared and Laser Engineering, 2014, 43(9): 2793-2797.

Resistance selection of blind sensitive element in PC PbS IRFPA detector fabrication

  • Received Date: 2014-01-15
  • Rev Recd Date: 2014-02-20
  • Publish Date: 2014-09-25
  • Resistance selection of blind element used in linear photoconductive (PC) PbS detector for counteracting background current was analyzed. It was found that the blind element resistance can be chosen to be same as, or to be a fixed ratio to that of relevant sensitive element. And the ratio should be equal with ratio of biases applied to blind element and relevant detector. Two linear PC 1 128 PbS infrared focal plane array (IRFPA) detectors, with sensitive element size of 100 m 100 m, and blind element size of 100 m 100 m and 200 m 50 m, were fabricated and their performance were tested by IRFPA test system. Results show that when the working condition satisfied average responsivity and average detectivety are same for using different blind elements. Results validate the feasibility that background output uniformity improvement of IRFPAs by tuning the resistance of blind element.
  • [1] Snchez F J, Rodrigo M T, Vergara G, et al. Progress onmonolithic integration of cheap IRFPAs of polycrystallinePbSe[C]//SPIE, 2005, 5783: 592-598.
    [2]
    [3] Rodrigo M T, Snchez F J, Torquemada M C, et al.Polycrystalline lead selenide x-y addressed uncooled focalplane arrays [J]. Infrared Physics Technology, 2003, 44:281-287
    [4]
    [5] Steven Jost, John Barret. Lead salt room-temperature MWIRFPA[C]//SPIE, 2001, 4369: 355-359.
    [6]
    [7]
    [8] Torquemada M C, Villamayor V, Rodrigo M T, et al.Polycrystalline PbSe x-y addressed uncooled FPAs[C]//SPIE,2003, 5074: 592-599.
    [9]
    [10] Cai Yi, Hu Xu. Short wave infrared imaging technology andits defence application [J]. Infrared and Laser Engineering,2006, 35(6): 643-647. (in Chinese)蔡毅, 胡旭. 短波红外成像技术及其军事应用[J]. 红外与激光工程, 2006, 35(6): 643-647.
    [11]
    [12] Chen Xiqu, Yi Xinjian, Wang Qiang. Low-noise readoutcircuit of VO2-based uncooled focal plane array [J]. JInfrared Millim Waves, 2006, 25(4): 246-250. (in Chinese)陈西曲, 易新建, 王强. 具有低噪读出特性的VO2 非致冷焦平面读出电路[J]. 红外与毫米波学报, 2006, 25(4): 246-250.
    [13]
    [14] Chen Xiqu, Li Xianghui, Yi Xinjian, et al. New readoutcircuit of uncooled infrared focal plane arrays without TEC[J]. Infrared and Laser Engineering, 2006, 35 (5): 551-554.(in Chinese)陈西曲, 李祥辉, 易新建,等. 新型无TEC 的非制冷IRFPA读出电路研究[J]. 红外与激光工程, 2006, 35(5): 551-554.
    [15] GB/T 17444-1998. The technical nonns for measurementand test of characteristic parameters of infrared focal planearrays[S]. Beijing: Chinese Standard Press, 1998. (in Chinese)GB/T 17444-1998. 红外焦平面阵列特性参数测试技术规范[S]. 北京:中国标准出版社, 1998.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(295) PDF downloads(239) Cited by()

Related
Proportional views

Resistance selection of blind sensitive element in PC PbS IRFPA detector fabrication

  • 1. China Airborne Missile Academy,Luoyang 471099,China;
  • 2. Aviation Key Laboratory of Science and Technology on Infrared Detector,Luoyang 471099,China

Abstract: Resistance selection of blind element used in linear photoconductive (PC) PbS detector for counteracting background current was analyzed. It was found that the blind element resistance can be chosen to be same as, or to be a fixed ratio to that of relevant sensitive element. And the ratio should be equal with ratio of biases applied to blind element and relevant detector. Two linear PC 1 128 PbS infrared focal plane array (IRFPA) detectors, with sensitive element size of 100 m 100 m, and blind element size of 100 m 100 m and 200 m 50 m, were fabricated and their performance were tested by IRFPA test system. Results show that when the working condition satisfied average responsivity and average detectivety are same for using different blind elements. Results validate the feasibility that background output uniformity improvement of IRFPAs by tuning the resistance of blind element.

Reference (15)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return