Design of high accuracy temperature control system of auroral imager light filter system

  • Received Date: 2014-10-15
  • Rev Recd Date: 2014-11-20
  • Publish Date: 2015-01-25
  • A high-accuracy temperature control system for light filter of auroral imager was proposed in the paper. Platinum resistance was used as the temperature sensor, and the temperature measuring circuit can collect the temperature with an accuracy of 0.05 ℃. A DSP was used as the main control unit, which implemented a full digital control system. The heater plate used constant current source circuit as its driving circuit, implementing the high precision and low noise heating power control. The mathematical model of the system was established, and the key parameters were identified from step response curves of the practical light filter system. The controller was designed based on the identified model and simulation results show the performance of the designed controller. Then, the parameters of the controller were tuned in experiments and experiment results show that better performance is obtained using optimized controller. At last, experiments results were discussed and show that high accuracy temperature control of the light filter system was implemented.
  • [1] Wang Yongmei, Fu Liping, Wang Yingjian. Review of space-based FUV aurora/airglow observations[J]. Process in Geophysics, 2008, 23(5): 1474-1479. (in Chinese)
    [2]
    [3]
    [4] Wu Yan, Tang Yi, Liu Jianpeng, et al. Optics design of far ultraviolet imaging spectrometer for ionosphere remote sensing[J]. Acta Optica Sinica, 2012, 32(1): 1-6. (in Chinese)
    [5] Yu Lei, Wang Shurong, Lin Guanyu. Review of space-based imaging spectrum technique development for Ionosphere observations[J]. Process in Geophys, 2012, 27(6): 2308-2315. (in Chinese)
    [6]
    [7]
    [8] Frank L A, Craven J D. Imaging results from dynamics explorer[J]. I Rev Geophys, 1988, 26: 249-252.
    [9]
    [10] Cogger L L, M urphree J S, Elphinstone R D, et al. The UV imager experiment on the swedish viking satellite: contributions to auroral physics[J]. Can J Phys, 1991, 69: 1032-1039.
    [11]
    [12] Adema J. Development of an ultraviolet auroral imager[C] //SPIE, 1999, 1344: 165-174.
    [13] Peng Ruyi, Fu Liping, Tao Ye. Study on the vacuum ultraviolet transmittance of barium fluoride crystals at different temperature[J]. Spectroscopy and Spectral Analysis, 2014, 34(3): 713-716. (in Chinese)
    [14]
    [15]
    [16] Zhou Zhen, Qi Zhongliang, Qin Yong, et al. Research on high-precision temperature measurement of constant temperature control system of semiconductor laser[J]. Chinese Journal of Engineering Design, 2012, 19(3): 221-235. (in Chinese)
    [17]
    [18] Li Lijing, Yang Hui, Ma Yingjian, et al. Research on the pulse-width modulation working mode and spectrum-related issues of high-precision temperature control[J]. Infrared and Laser Engineering, 2013, 42(6): 1588-1592. (in Chinese)
    [19]
    [20] Yu Tao, Xu Shuyan, Song Kefei. Auto-focusing system based on temperature for space camera[J]. Infrared and Laser Engineering, 2012, 41(8): 2085-2089. (in Chinese)
    [21] Li Yanwei, Yang Hongbo, Cheng Zhifeng, et al. Thermal/structural/optical integrated design for optical window in aerial remote sensor[J]. Infrared and Laser Engineering, 2012, 41(8): 2102-2106. (in Chinese)
    [22]
    [23] Dai Junke, Jiang Haiming, Zhong Qirun, et al. LD temperature control system based on self-tuning fuzzy PID algorithm[J]. Infrared and Laser Engineering, 2014, 43(10): 3287-3291. (in Chinese)
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(389) PDF downloads(241) Cited by()

Related
Proportional views

Design of high accuracy temperature control system of auroral imager light filter system

  • 1. Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China

Abstract: A high-accuracy temperature control system for light filter of auroral imager was proposed in the paper. Platinum resistance was used as the temperature sensor, and the temperature measuring circuit can collect the temperature with an accuracy of 0.05 ℃. A DSP was used as the main control unit, which implemented a full digital control system. The heater plate used constant current source circuit as its driving circuit, implementing the high precision and low noise heating power control. The mathematical model of the system was established, and the key parameters were identified from step response curves of the practical light filter system. The controller was designed based on the identified model and simulation results show the performance of the designed controller. Then, the parameters of the controller were tuned in experiments and experiment results show that better performance is obtained using optimized controller. At last, experiments results were discussed and show that high accuracy temperature control of the light filter system was implemented.

Reference (23)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return