Li Bin, Wu Haiying, Wang Wentao, Liu Peng. Design of a simple infrared calibration system[J]. Infrared and Laser Engineering, 2014, 43(2): 458-463.
Citation: Li Bin, Wu Haiying, Wang Wentao, Liu Peng. Design of a simple infrared calibration system[J]. Infrared and Laser Engineering, 2014, 43(2): 458-463.

Design of a simple infrared calibration system

  • Received Date: 2013-06-05
  • Rev Recd Date: 2013-07-15
  • Publish Date: 2014-02-25
  • In order to solve problem of the existing infrared calibration system as laboratory calibration and engineering calibration, a simple infrared calibration system was designed for practical applications in the fields. Its response model was established. Key parameters such as the standard radiation source were also analyzed in detail. In addition, an assistant system was designed and performed in practical measurements. A infrared radiation calibration system was bulit up and the corresponding experiment was performed. Compared with the laboratory calibration results, it was shown that the designed setup could be employed in infrared calibration and radiation measurement with attractive precision and useful simplicity.
  • [1]
    [2] Xu Nanrong, Bian Nanhua. Infrared Radiation and Guidance[M]. Beijin: National Defence Industry Press, 1997. (in Chinese)
    [3] Tang Jia, Gao Xin. Calibration method for infrared radiation characteristics measuring system of test range[J]. Infrared and Laser Engineering, 2006, 35(S1): 266-270. (in Chinese)
    [4] 徐南荣, 卞南华. 红外辐射与制导[M]. 北京: 国防工业出版社.1997.
    [5] Cao Lihua, Lin Ning, Yang Ciyin, et al. Radiance calibration for 3-5 m infrared detector[J]. Infrared and Laser Engineering, 2012, 41(4): 858-864. (in Chinese)
    [6]
    [7]
    [8] Luo Maojie, Zhou Jinmei, Fu Jingneng, et al. Integration time as variable for radiometric calibration of infrared system[J]. Infrared and Laser Engineering, 2013, 42(1): 36-40. (in Chinese)
    [9] Xing Qianglin. Calibration for FPA infrared radiation measuring system[J]. Journal of spacecraft TT C technology, 2007, 26(4): 68-71. (in Chinese)
    [10] 唐嘉, 高昕. 靶场红外辐射特性测量系统标定方法研究[J]. 红外与激光工程, 2006, 35(S1): 266-270.
    [11] Li Xiansheng, Ren Jianwei, Zhang Liguo, et al. Research on a radiometric calibration device for a large aperture infrared opto-electric system on spot[J]. Journal of Optoelectronics Laser, 2006, 17(2): 175-178. (in Chinese)
    [12]
    [13]
    [14] 曹立华, 李宁, 杨词银, 等. 红外探测器的辐射定标[J]. 红外与激光工程, 2012, 41(4): 858-864.
    [15]
    [16]
    [17] 罗茂捷, 周金梅, 傅景能, 等. 考虑积分时间变量的红外系统辐射响应定标[J]. 红外与激光工程, 2013, 42(1): 36-40.
    [18]
    [19]
    [20] 邢强林. 红外焦平面成像探测辐射特性测量定标方法研究[J]. 飞行器测控学报, 2007, 26(4): 68-71.
    [21]
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(365) PDF downloads(194) Cited by()

Related
Proportional views

Design of a simple infrared calibration system

  • 1. China Huayin Ordnance Test Center,Huayin 714200,China

Abstract: In order to solve problem of the existing infrared calibration system as laboratory calibration and engineering calibration, a simple infrared calibration system was designed for practical applications in the fields. Its response model was established. Key parameters such as the standard radiation source were also analyzed in detail. In addition, an assistant system was designed and performed in practical measurements. A infrared radiation calibration system was bulit up and the corresponding experiment was performed. Compared with the laboratory calibration results, it was shown that the designed setup could be employed in infrared calibration and radiation measurement with attractive precision and useful simplicity.

Reference (21)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return