可变光片照明系统设计

Design of variable light-sheet illumination system

  • 摘要: 为解决目前光片荧光显微镜光片厚度单一的问题,基于变倍扩束原理进行了可变光片照明系统设计。首先,对光片照明系统各组成部分进行了高斯光学计算,得到光片厚度与扩束比的关系以及扩束比与各组元垂轴放大率、焦距的关系;然后,设计了基于10倍扩束的可变光片照明系统,得到厚度和长度连续可变的光片;最后,对光片参数、均匀性及系统的公差进行分析。设计结果表明,连续可变光片的厚度为3.33~33.3 m,在YOZ平面上60%的光片高度区域内,低(1)、中(6)和高(10)扩束比下的照度均匀性分别达到0.65、0.4和0.61。公差分析表明,光片厚度在1扩束比时的最大改变量小于设计值的15%,在6和10扩束时小于6%。设计实现了光片厚度的连续变化,且在60%的光片高度区域内有利于样本的观察。

     

    Abstract: To solve the problem of the single thickness of the light-sheet fluorescence microscopy, the design of the variable light-sheet illumination system was carried out based on zoom beam expanding. First, each group of the light-sheet illumination system was calculated using Gaussian optics to obtain the relation between the thickness of the light-sheet and the expansion ratio as well as the relation among the expansion ratio, the lateral magnification and focal length of each group. Then a variable light-sheet illumination system based on 10beam expanding was designed to generate the light-sheet with continuously variable thickness and length. Finally, the parameters and uniformity of the light-sheet and the system tolerance were analyzed. The results show that the thickness of the continuously variable light-sheet is 3.33 m to 33.3 m, and the illumination uniformity is 0.65, 0.4 and 0.61 on the YOZ plane within 60% light-sheet height at low (1), medium (6) and high (10) expansion ratios, respectively. Tolerance analysis shows that the maximum change of the light-sheet thickness is less than the 15% of design value at expansion ratio of 1, less than 6% at 6and 10. The design realizes the continuous variation of the light sheet thickness, and the region of 60% light-sheet height is favorable for the observation of the sample.

     

/