李响, 李小明, 张家齐, 柳鸣, 孟立新, 张立中. 多节点激光通信天线“一体式”SiC/Al轻量化摆镜[J]. 红外与激光工程, 2019, 48(S1): 198-204. DOI: 10.3788/IRLA201948.S118001
引用本文: 李响, 李小明, 张家齐, 柳鸣, 孟立新, 张立中. 多节点激光通信天线“一体式”SiC/Al轻量化摆镜[J]. 红外与激光工程, 2019, 48(S1): 198-204. DOI: 10.3788/IRLA201948.S118001
Li Xiang, Li Xiaoming, Zhang Jiaqi, Liu Ming, Meng Lixin, Zhang Lizhong. Integrated SiC/Al lightweight tip-tilt mirror of multi-node laser communications antenna[J]. Infrared and Laser Engineering, 2019, 48(S1): 198-204. DOI: 10.3788/IRLA201948.S118001
Citation: Li Xiang, Li Xiaoming, Zhang Jiaqi, Liu Ming, Meng Lixin, Zhang Lizhong. Integrated SiC/Al lightweight tip-tilt mirror of multi-node laser communications antenna[J]. Infrared and Laser Engineering, 2019, 48(S1): 198-204. DOI: 10.3788/IRLA201948.S118001

多节点激光通信天线“一体式”SiC/Al轻量化摆镜

Integrated SiC/Al lightweight tip-tilt mirror of multi-node laser communications antenna

  • 摘要: 为了降低多节点激光通信天线的工作包络尺寸、提高二维摆镜的运动控制精度,避免镜体材料与支撑材料性能差异引起的面形改变,提出了一种包含支撑结构的一体式轻量化摆镜。采用高体分SiC/Al作为材料,进行了摆镜以及支撑结构的一体化设计,提高了摆镜面形的力、热稳定性,可直接连接转台俯仰轴座,使摆镜回转中心距镜面的距离缩短至20 mm。有限元分析表明,一体式摆镜基频为1 337 Hz,在(205)℃工作温度范围内,面形误差峰谷值(PV)优于0.121,面形误差均方根值(RMS)优于0.031。使用ZYGO干涉仪对摆镜的面形进行检测,结果表明在(205)℃温度范围内摆镜面形PV值优于0.163,RMS值优于0.029,满足激光通信天线对于摆镜面形/25(RMS)的指标要求。

     

    Abstract: In order to reduce the range of movement of multi-node laser communication antennas, improve the motion control accuracy of two-dimensional tip-tilt mirror, avoid changing of mirror surface shape caused by the difference material performance between the mirror and the support, a integrated lightweight tip-tilt mirror with a supporting structure was proposed. Integrated design of tip-tilt mirror and support structure was conducted using material of high volume fraction SiC/Al. The thermal and mechanics stability of the mirror surface shape was improved. It can be mounted directly on the elevation axle seat, and the distance between the tip-tilt mirror rotation axis and the surface was shortened to 20 mm. The result of finite element analysis shows that the eigenfrequency of the tip-tilt mirror was of 1 337 Hz. The peak valley value(PV) of tip-tilt mirror surface shape error was better than 0.121, and root mean square value(RMS) was better than 0.031 in the range of (205)℃. Using ZYGO interference to test the mirror surface shape error, test results show that the peak-valley value of tip-tilt mirror surface shape error is better than 0.163 and root mean square value is better than 0.029 in the ambience of (205)℃ Parameter requirement of laser communication antenna for tip-tilt mirror surface shape error /25(RMS) is satisfied.

     

/

返回文章
返回