Offner型成像光谱仪前置光学系统设计

Design of fore telescope system for Offner imaging spectrometer

  • 摘要: 针对Offner 型成像光谱仪结构特点,总结了其前置望远系统的选型及设计原则;介绍了一种大视场、长焦距、像方远心离轴三反光学系统的设计方法;利用该方法优化设计了一款焦距800 mm,视场达8.60.148,工作波段0.9~5 m 的星载Offner 型成像光谱仪的前置望远光学系统。对其性能分析表明,在Nyquist 频率16.7 lp/mm 处,各谱段的调制传递函数值均在0.65 以上,接近衍射极限,完全满足成像质量要求。同时证明了该设计方法可行,所设计系统结构紧凑,较易加工,适于空间遥感用Offner 型成像光谱仪。

     

    Abstract: In allusion to the specific structural characters of Offner imaging spectrometer, the fundamental design principles of its fore telescope were analyzed. A novel method to design the wide FOV, long focal length and telecentric off-axis three-mirror anastigmatic (TMA) optical system was presented. For the projective demand, a fore telescope system for Offner imaging spectrometer was designed. Its focal length was 800 mm. Its FOV was 8.60.148, and the operation spectrum band was from 0.9 m to 5 m. The evaluation results of its imaging quality demonstrate that the MTF of each spectrum band is higher than 0.65 at the Nyquist frequency 16.7 lp/mm. The imaging quality has reached the diffraction-limitation, which satisfies the pre-designed requirement. Therefore, the design method is feasible. The designed telescope system is compact, easy to be fabricated and suitable for space borne Offner imaging spectrometer.

     

/

返回文章