Volume 43 Issue 12
Jan.  2015
Turn off MathJax
Article Contents

Hou Lifei, Du Huabing, Li Jin, Ren Kuan, Yang Yimeng, Cui Yanli, Dou Yanjuan, Yang Guohong, Liu Shenye. Performance of X-ray diode with a smaller cathode area[J]. Infrared and Laser Engineering, 2014, 43(12): 4040-4044.
Citation: Hou Lifei, Du Huabing, Li Jin, Ren Kuan, Yang Yimeng, Cui Yanli, Dou Yanjuan, Yang Guohong, Liu Shenye. Performance of X-ray diode with a smaller cathode area[J]. Infrared and Laser Engineering, 2014, 43(12): 4040-4044.

Performance of X-ray diode with a smaller cathode area

  • Received Date: 2014-04-05
  • Rev Recd Date: 2014-05-15
  • Publish Date: 2014-12-25
  • It will be helpful for soft X-ray Spectrometer that X-Ray diode (XRD) can be improved to be more compact. And it will be convenient that other X-ray diagnosis apparatus integrate the mini - XRD. A new XRD with smaller cathode was designed, which owned more reasonable capacitor for power storage and smaller size. Microwave performances of the output part were simulated. The results show that signal distortion and reflection is ignorable in the range of 0 -20 GHz and experiments requirements can be satisfied. And detector character test experiments were carried on the short pulse laser equipment. Data indicates that capability of temporal resolution was improved by 20%. Because of the study of detector with smaller cathode area, XRD will be more popular for estimating of X-ray flux.
  • [1]
    [2] Zhang Jun, Pei Wenbin, Sui Chengzhi, et al. Radiation temperature and X-ray conversion efficiancy for laser-cavity target [J]. Acta Physica Sinica, 1991, 40(3): 424-432. (in Chinese) 张钧,裴文兵,隋成之,等. 激光柱型腔靶X 光温度和X 光 转换效率[J]. 物理学报, 1991, 40(3): 424-432.
    [3]
    [4] Lindl J. Development of the indirect-drive approach of ICF and the target physics basis for ignition and gain [J]. Phys Plasmas, 1995, 2(11): 3933-4024.
    [5] Lindl J, Amendt P, Berger R L, et al. The physics basis for ignition using indirect-drive targets on the national ignition facility[J]. Phys Plasmas, 2004, 11(2): 339-491.
    [6]
    [7]
    [8] Yang Jiamin,Ding Yaonan, Zheng Zhijian, et al. Quantitative measurement of soft-X-ray spectrumusing transmission grating spectrometer[J]. Acta Physica Sinica, 2001, 50(9): 1723-1728. (in Chinese) 杨家敏,丁耀南,郑志坚,等. 软X 光能谱定量测量技术研 究[J]. 物理学报,2001, 50(9): 1723-1728.
    [9] Sorce C, Schein J, Weber F, et al. Soft X-ray power diagnostic improvements at the Omega laser facility[J]. Review of Scientific Instruments, 2006, 77(10): 10E518-1-10E518-4.
    [10]
    [11] Idzorek G C, Tierney T E, Lockard T E, et al. Reproducible, rugged, and inexpensive photocathode X-ray diode[J]. Review of Scientific Instruments, 2008, 79(10): 10E922-1-10E922-3.
    [12]
    [13]
    [14] Hou Lifei, Yi Rongqing, Liu Shenye, et al. Laser and plasma pulse source for calibration[J]. High Power Laser and Particle Beams. 2007, 19(1): 79-82.(in Chinese) 侯立飞,易荣清,刘慎业,等. 激光等离子体脉冲标定源[J]. 强激光与粒子束,2007, 19(1): 79-82.
    [15]
    [16] Sun Kexu, Yang Jianguo, Zheng Zhijian. A subke V X-ray spectrometer used in laser plasma interaction experiments[J]. High Power Laser and Particle Beams, 1990, 2 (1): 16-22. (in Chinese) 孙可煦,杨建国,郑志坚. 用于激光等离子体诊断的亚千 X 光能谱仪[J]. 强激光与粒子束, 1990, 2(1): 16-22.
    [17] Hou Lifei, Yang Guohong, Liu Shenye, et al. Development of X-ray diode with high performences [J]. High Power Laser and Particle Beams, 2011, 23(3): 652-656. (in Chinese) 侯立飞,杨国洪,刘慎业,等. 高性能X 光二极管的研制. 强激光与粒子束, 2011, 23(3): 652-656.
    [18]
    [19]
    [20] Sun Kexu, Jiang Shao'en, Yi Rongqing, et al. Research on time characteristics of soft X-ray diode [J]. Acta Physica Sinica, 2006, 55(1): 68-75. (in Chinese) 孙可煦,江少恩,易荣清,等. X光二极管时间特性研究[J]. 物理学报, 2006, 55(1): 68-75.
    [21] Jiang Shao'en, Sun Kexu, Peng Nengling, et al. Development on mini X-ray diode [J]. Nuclear Electronics Detection Technology, 2004, 24(6): 571-574. (in Chinese) 江少恩,孙可煦,彭能岭,等. 小型X 光二极管的研制[J]. 核电子学与探测技术, 2004, 24(6): 571-574.
    [22]
    [23] Chen Liang, Zhang Yan, Chen Jun, et al. Fabrication and characterization of back-illuminated GaN/AlGaN p-i-n UV detector with high performance [J]. Infrared and Laser Engineering, 2007, 36(6): 928-933. (in Chinese) 陈亮,张燕,陈俊,等. 高性能背照式GaN/AlGaN p-i-n 紫 外探测器的制备与性能[J]. 红外与激光工程, 2007, 36 (6): 928-931
    [24]
    [25] Bai Yun, Shao Xiumei, Chen Liang, et al. Effect of electron irradiation on the GaN-based p-i-n UV detector[J]. Infrared and Laser Engineering. 2008, 37(2): 270-273. (in Chinese) 白云,邵秀梅,陈亮,等. GaN 基紫外探测器的电子辐照效 应[J]. 红外与激光工程, 2008, 37(2): 270-273.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(409) PDF downloads(174) Cited by()

Related
Proportional views

Performance of X-ray diode with a smaller cathode area

  • 1. Laser Fusion Research Center,China Academy Engineering Physics,Mianyang 621900,China;
  • 2. Institute of Applied Electronics,China Academy Engineering Physics,Mianyang 621900,China

Abstract: It will be helpful for soft X-ray Spectrometer that X-Ray diode (XRD) can be improved to be more compact. And it will be convenient that other X-ray diagnosis apparatus integrate the mini - XRD. A new XRD with smaller cathode was designed, which owned more reasonable capacitor for power storage and smaller size. Microwave performances of the output part were simulated. The results show that signal distortion and reflection is ignorable in the range of 0 -20 GHz and experiments requirements can be satisfied. And detector character test experiments were carried on the short pulse laser equipment. Data indicates that capability of temporal resolution was improved by 20%. Because of the study of detector with smaller cathode area, XRD will be more popular for estimating of X-ray flux.

Reference (25)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return